电脑桌面
添加小米粒文库到电脑桌面
安装后可以在桌面快捷访问

Biograph/Lenstar与IOLMaster测量眼轴、角膜曲率及前房深度的比较VIP免费

Biograph/Lenstar与IOLMaster测量眼轴、角膜曲率及前房深度的比较_第1页
1/5
Biograph/Lenstar与IOLMaster测量眼轴、角膜曲率及前房深度的比较_第2页
2/5
Biograph/Lenstar与IOLMaster测量眼轴、角膜曲率及前房深度的比较_第3页
3/5
26华眼视光学j视觉科学杂志2011q-4月第13卷第2期ChinJOptomOphthahnolVisSci,April2011.Vo1.13.No.2Biograph/Lenstar与IOLMaster测量眼轴、角膜曲率及前房深度的比较黄锦海陈世豪温岱宗王勤美【摘要】目的比较[姒』种圯学十H十,物测量仪Biogiaph/1eHstar和IOLMaster测量眼轴fA)、角膜半(Kl、K2和Kn1)币』I前(A(1I)l的肄,分析_二肯的一敢性,为临床使用提供依据方法前瞻临床研究..近视忠34例(68眼),等效球镜为一0.O5~10.()(】D,平均(一4.11±2.31)D,分别应耳JBioglaph/lenslm’和101Maste~进行AL、Kl、K2、Kin和ACD测量,两种仪器问以j:指标的采用酣刈t检验,两种仪fH】洲所僻数据的相戈性采用Pearson相关分析,两种仪器问测量所得数据的·致性采JHl~land~Ahanm统计分析。结果Biegraph/1enstai和IOLMaster测量AL的半均值分别为(25.39±l,09)ram和(2537±1.08)ram,差异具有统汁学意义(t=8.855,P<0.01);两荷的K1、K2和Km差异均有统汁学意义(f=一2.511,P=0.014;l_=一2.4l3,,L0.0l9;f=一2.893,P=0.005):ACD伉分别为f3.80_+0.26)lnm棚(3.78_+0.26)mm,箍蚪几统计学意义,,种仪问所有的测挝参数均具有密切的线性榭天(r均>0.90.01)两种方法测AI和ACD一致性较好,而K1、K2和Km一致性较差结论Bi()graph几enstaI测趟部无明质性疾病人甘千的眼轴长度及前房深度与IOIMaster具有良好的一致性.、时角膜曲率的测,『从j者测一敛性较差,俺J}】中需结合临床意义进一步对仪器的适』十]范吲7JII以判断【关键词】BiIlgral,l1/Jenstm;IOIMaster;轴;角膜曲率;前房深度ComparisonofBiograph/LenstarandIOLMasterinthemeasurementofaxiallength,cornealcurvature,andanteriorchamberdepthHUANGdin—hai,CHENShi一no,WENDai—o7g,WANGQin—mei.eHospitalofWenzhouMedicalCollege,Wenzhou325027,ChinaCorrespondingauthor:WANGQin-mei,Email:wqm6@mail.eye.∞.cn【Abstract】0bjectiveToassesstheaccuracyofaxiallength(AL),cornealcurvature(K1,K2aridKm)andanteriorehamherdepth(ACD)measurenieutswiththeBingraph/l~enstarLS900biometerarl‘ltheIO1Master.MethodsInthisprospectiveclinicalstudy.68eyesof34myopes.whosesphe,’ie,alequivalentwere一0.50一一10.00D,withanaverageof(一4.11±2.31)D.AL,K1,K2,KinandACDottIjesemyopesweremeasuredwiththeBiograph/LenstarandIOLMasterbiometer.Datawe!’eanalyzedusingapairedsamplesttest.1inearregt’essionandBland—Altmanplots.ResultsThemeanALandACI)nleaSUl’edbytheBiograph/LI1sLarand1OIMasterwere(25.39+1.09)mm,(25.37-+1.08)ram,and(3.80_+0.26)taro,f3.78_+0.26)mm,respectivelY.ThereweresignificantdifferencesbetweenttleresuhsofthesetwomethodsinAL“=8.855,P0.9fi,ral1.P<0.O1f0ral1).rheBland-Ahmanshowedthatthetwodevieeshaduon-e1)ullIalableresultsf0rcornealcurvaturebuteomparableresultsforALandAC1).Conclusionrr}】eA1andACI)valuesobtainedwiththeBiograph/[enstararecorrelatedverywelltothoseoftheIO1Master.Itisimportantmnoteinclinicalpractice.thateornealcurvaturevaluesacquiredbythesedevieesareI1rJ【directlyintmchangeable.【Keywords】Biograph/I,enstar;1OIMaster;Axiallength;Cornealcurvature;Anterim’chamherdepthL)O1:l0.3760/cma.j.issu.1674—845X.20l1.02.()11作肯俺:325027浙江温州,温州医学院附属眼视光医院通信作者:勤荚,nmil:wqm6@mail.eye.acn·论著·准确的眼球生物参数测量对于眼内屈光手术人品状体屈光度的计算、青光眼以及屈光不正等眼病诊断和治疗具有很重要的临床意义。l999年研...

1、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
3、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。

碎片内容

Biograph/Lenstar与IOLMaster测量眼轴、角膜曲率及前房深度的比较

确认删除?
VIP
微信客服
  • 扫码咨询
会员Q群
  • 会员专属群点击这里加入QQ群
客服邮箱
回到顶部