BT-GL02-09XXXXXXXX2X300MW 扩建工程#3 锅炉蒸汽系统吹扫调试方案XXXXXXXX 科学讨论院二○○六年九月签字页 批准: 审核: 编写: 目 录1.编制依据...........................................................................................................42.调试目的...........................................................................................................43.调试质量目标...................................................................................................44.系统简介...........................................................................................................55.锅炉冲管范围、流程及参数...........................................................................66.冲管临时设施的安装及技术要求...................................................................77.锅炉首次点火吹管前应具备的条件...............................................................98.调试步骤.........................................................................................................149.组织分工.........................................................................................................1610.环境、职业健康、安全、风险因素控制措施...........................................1911.附录...............................................................................................................231.编制依据1.1《火力发电厂基本建设工程启动及竣工验收规程(1996 年版)》1.2《电力建设施工及验收技术法律规范》锅炉机组篇(1996 年版)1.3《电力建设施工及验收技术法律规范》管道篇(1996 年版)1.4《火电工程调整试运质量检验及评定标准》(1996 年版)1.5《火电工程启动调试工作规定》(1996 年版)1.6《火电机组启动蒸汽吹管导则》(1998 年版)1.7《电力工业锅炉监察规程》1.8《火电工程调整试运质量检验及评定标准》(1996 年版)1.9 设计图纸及设备设明书2.调试目的新安装机组,锅炉过热器、再热器及其蒸汽管道内部的清洁程度,对机组的安全经济运行及能否顺利投产关系重大。为了清除在制造、运输、保管、安装过程中管内积存的杂物和产生的锈蚀,必须对锅炉的过热器、再热器及蒸汽管道进...