目 录一、编制依据 ....................................................................................... 1 二、工程概况 ........................................................................................ 1 三、施工部署 .........................................................................................4 四、外挂架设计、与施工.......................................................................44.1 结构施工外脚手架的选择 ...............................................................44.2 外挂架设计 ........................................................................................44.3 外挂架组装 .......................................................................................11 4.4 外挂架提升 .......................................................................................11五、外挂架安装注意事项.........................................................................14六、外挂架计算书..................................................................................... 15一、编制依据 1.1 设计图纸 1.2 施工组织设计 1.3 《高层钢筋砼结构设计与施工规程》 JGJ3—2025 1.4 《大模板多层住宅设计与施工规程》 JGJ20—841.5 《建筑施工安全检查标准》 (JGJ59-99)1.6 《建筑施工扣件式钢管脚手架安全技术法律规范》 (JGJ130-2025)1.7 《建筑施工高处作业安全技术法律规范》 (JGJ80-91) 1.8 《钢结构设计法律规范》 GB50017-20251.9 《建筑结构荷载法律规范》 GB50009-20012.0 《建筑工程大模板技术规程》 JGJ74-20252.1 《全钢大模板应用技术规程》 DBJ01-89-200二、工程概况XX 区 XX 农场东至 XX 路,西至 XX 大街,北至 XX 二路,南至 XXX 园一期工程本项目为本地块主要功能为住宅。 3#楼地下 2 层地上 9 层建筑高度 26.25m 建筑面积 16357.92㎡。4#楼地下2 层地上 14 层建筑高度 40.25m 总建筑面积 16261.15 ㎡、7#地下 2 层地上 12 层建筑高度34.65m 建筑面积 25939.32㎡和 8#楼地下 2 层地上 12 层建筑面积 14249.85㎡高度 36.65m,总建筑面积共 72808.24㎡。结构概况:三、施工部署 序号项 目内 容1结构形式结构剪力墙结构...