基于金纳米簇与碳酸氢根缓冲体系定量检测钴离子目录摘要........................................................................................................................................11.前言...................................................32.实验部分...............................................42.1实验试剂............................................42.2实验仪器............................................52.3实验步骤.............................................52.3.1金纳米簇(BSA-AuNCs)的制备........................52.3.2钴离子在碳酸氢根缓冲溶液中对金纳米簇的猝灭.......52.3.3钴离子浓度对金纳米簇猝灭效果的分析...............62.3.4碳酸氢根缓冲体系中,其他离子对金纳米簇猝灭效果的影响.....................................................62.3.5实样检测.........................................63.结果与讨论.................................................................................................................63.1牛血清蛋白和金纳米簇的紫外可见吸收光谱..............63.2钴离子在碳酸氢根缓冲溶液中对金纳米簇的猝灭...........73.3钴离子和碳酸氢根缓冲体系对金纳米簇猝灭条件的优化.....83.3.1碳酸氢根缓冲溶液的pH的影响......................83.3.2反应时间的影响...................................93.4金纳米簇的猝灭程度与钴离子浓度的线性关系探索.........93.5干扰离子对金纳米簇猝灭程度的影响...................113.6实际水样的测定与加标回收...........................113.7一种可能的机理......................................124.结论..................................................135.参考文献..............................................136.致谢..................................................15摘要在本研究中,我们利用金纳米簇的强荧光性能,在碳酸氢根缓冲体系下实现钴离子的定量检测。首先我们用牛血清蛋白(BSA)合成金纳米簇,并且发现在碳酸氢根体系中,钴离子可以很好的使金纳米簇猝灭。当钴离子浓度范围为0.8μmol/L--20μmol/L时,钴离子浓度与金纳米簇的猝灭程度之间存在着良好的线性关系。由此建立了一种基于荧光纳米簇的钴离子定量方法,该方法检测限可达0.32μmol。利用该荧光探针对自来水样进行了分析测定和加标回收,取得了良好的效果。关键词:钴离子,碳酸氢根,金纳米簇,猝灭,荧光探针AbstractInthisstudy,weusedthestrongfluorescencepropertiesofgoldnanoclusterstoachievequantitativedetectionofcobaltionsinbicarbonatebuffersystems.Firstly,weusedbovineserumalbumen(BSA)tosynthesizegoldnanoclusters.Itwasfoundthatinthebicarbonatesystem,cobaltionscanwellquenchthegoldnanoclusters.Whenthecobaltionconcentrationisintherangeof0.8μmol/L--20μmol/L,thereisagoodlinearrelationshipbetweenthecobaltionconcentrationandthedegreeofgoldnanoclusterquenching.Accordingtothis,amethodforquantifyingcobaltionsbasedonfluorescentnanoclusterswasdeveloped.Thedetectionlimitofthismethodisupto0.32μmol.Thefluorescentprobeswereusedtoanalyzethetapwaterandtherecoveryrateofthesamplewaterwastestedandgoodresultswereobtained.Keywords:cobaltions,bicarbonate,goldnanocluster,quench,fluorescentprobe1.前言工业活动产生的废水中污染物种类很多,包含碳氢化合物、苯酚及其衍生物、含硫、氮、卤素的有机化合物和各种重金属离子[1]。在这些污染物中,矿冶、机械制造、化工、电子、仪表等工业产生了许多含重金属离子(镉、铬、铜、汞、钴、镍等)的废水。如果用含重金属离子的废水和污泥对农田进行农田灌溉和施肥,不仅使土壤受到污染,同时会进一步污染水体,造成重金属离子在农作物生长和水生生物中的富集和积蓄,通过食物链对人体造成严重危害此外若人类直接饮用含有重金属离子的水,会诱发各种疾病...