电脑桌面
添加小米粒文库到电脑桌面
安装后可以在桌面快捷访问

电缆敷设接线施工方案(DOC30页)VIP免费

电缆敷设接线施工方案(DOC30页)_第1页
1/26
电缆敷设接线施工方案(DOC30页)_第2页
2/26
电缆敷设接线施工方案(DOC30页)_第3页
3/26
大唐双鸭山热电有限公司2X200MW锅炉烟气脱硝改造工程电缆敷设(电气)施工方案编写:审核:批准:凯天环保科技股份有限公司双鸭山脱硝改造项目部2015年04月02日目录1.工程概况和工程量.............................................................11.1工程概况...................................................................11.2工程量和工期...............................................................32.编制依据.....................................................................53.作业前的条件和准备..........................................................53.1技术准备...................................................................53.2作业人员配置、资格.........................................................63.3作业工机具及仪器仪表.......................................................63.4材料和设备.................................................................73.5安全器具...................................................................73.6工序交接...................................................................73.7其他.......................................................................84.作业程序、方法..............................................................84.1施工方案...................................................................84.2施工工艺流程...............................................................84.3施工方法及要求............................................................115.质量控制点的设置和质量通病预防..............................................215.1质量目标..................................................................215.2质量控制及通病预防........................................................215.3作业过程中控制点设置......................................................215.4质量标准及要求............................................................22※5.5强制性条文..............................................................226.作业的安全要求和环境条件...................................................226.1作业的安全危害因素辨识和控制..............................................226.2环境条件..................................................................236.3消防管理..................................................................236.4作业中应急处置预案........................................................236.5作业的安全基本要求及措施..................................................246.6现场文明施工要求..........................................................247附录.......................................................................247.1电缆线路施工强制性条文执行情况检查表......................................247.2重大危险源辨识清单及预防措施..............................................207.3重要环境因素辨识评价及预防措施............................................211.工程概况和工程量1.1工程概况大唐双鸭山热电厂位于黑龙江省双鸭山市,电厂已经投产发电。在此环境下新增安装两台炉脱硝装置及配套设施。本烟气脱硝工程采用以液氨为还原剂的催化还原法(SCR),总平面布置的格局基本上是由工艺流程确定,脱硝工程区域划分为脱硝区域和氨制备区域,脱硝区域设备布置在1#机、2#机锅炉后,电除尘器前。主要建筑施工为反应区和氨区及道路平整及地面硬化,设备安装有脱硝钢结构、脱硝烟道、氨气空气混合器以及SCR反应器。氨制备区域主要设备有氨储存罐、卸料压缩机、氨稀释罐、氨蒸发槽、缓冲槽、污水池及污水泵。本工程电缆敷设应遵照《电力工程电缆设计规范》GB50217-2007的要...

1、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
3、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。

碎片内容

电缆敷设接线施工方案(DOC30页)

确认删除?
VIP
微信客服
  • 扫码咨询
会员Q群
  • 会员专属群点击这里加入QQ群
客服邮箱
回到顶部