绝缘电阻测试记载(一)【2】质控(电)表4.3.4-2共页第页单位(子单位)工程名称施工单位气象型号规格兆欧表ZC254装备或线路名称装备位号或体系回路编号500V07068401泉州市计量所晴电压等级出厂编号测试日期气温(℃)检定单位检定有用期11231122℃检定证书编号(QJ)D104/0900197总配电箱ZAL1WL1500500500500500500500500500500WL2500500500500500500500500500500WL3500500500500500500500500500500WL4500500500500500500500500500500WL5500500500500500500500500500500WL6500500500500500500500500500500WL7备用ABBCCA绝缘电阻实测值︵MΩ︶ANBNCNAPEBPECPENPEAEBECENE消失问题处理情形结论无经测试:线路绝缘优越,相符设计要乞降《建筑电气工程施工质量验收规范》(GB50303)的划定.质检员施工单位施工员测试员绝缘电阻测试记载(一)专业监理工程师(扶植单位项目专业技巧负责人)第1页,-共21页质控(电)表4.3.4-2共页第页单位(子单位)工程名称施工单位气象型号规格兆欧表ZC254装备或线路名称装备位号或体系回路编号500V07068401泉州市计量所晴电压等级出厂编号测试日期气温(℃)检定单位检定有用期11231122℃检定证书编号(QJ)D104/0900197配电箱1AL1W1500500500500500500500500500500W2500500500500500500500500500500W3W4W5500500500500500500500500500500W6W7W8W9W10W11ABBCCA绝缘电阻实测值︵MΩ︶ANBNCNAPEBPECPENPEAEBECENE消失问题处理情形结论20050080100500500200200500200200500500500500500200200100500200100500500无经测试:线路绝缘优越,相符设计要乞降《建筑电气工程施工质量验收规范》(GB50303)的划定.质检员施工单位施工员测试员绝缘电阻测试记载(一)专业监理工程师(扶植单位项目专业技巧负责人)质控(电)表4.3.4-2共页第页第2页,-共21页单位(子单位)工程名称施工单位气象型号规格兆欧表ZC254装备或线路名称装备位号或体系回路编号500V07068401晴电压等级出厂编号测试日期气温(℃)检定单位泉州市计量所检定有用期11231122℃检定证书编号(QJ)D104/0900197配电箱1AL2W1500500500500500500500500500500W2500500500500500500500500500500W3500500500500500500500500500500W4W5W6W7W8ABBCCA绝缘电阻实测值︵MΩ︶ANBNCNAPEBPECPENPEAEBECENE消失问题处理情形结论20010060500100100100200150无经测试:线路绝缘优越,相符设计要乞降《建筑电气工程施工质量验收规范》(GB50303)的划定.质检员施工单位施工员测试员绝缘电阻测试记载(一)专业监理工程师(扶植单位项目专业技巧负责人)质控(电)表4.3.4-2共页第页单位(子单位)工程名称第3页,-共21页施工单位气象型号规格兆欧表ZC254装备或线路名称装备位号或体系回路编号500V晴电压等级出厂编号07068401测试日期气温(℃)检定单位泉州市计量所检定有用期11231122℃检定证书编号(QJ)D104/0900197配电箱2AL2W1500500500500500500500500500500W2500500500500500500500500500500W3500500500500500500500500500500W4W5W6W7W8ABBCCA绝缘电阻实测值︵MΩ︶ANBNCNAPEBPECPENPEAEBECENE消失问题处理情形结论200100150200500100100200150无经测试:线路绝缘优越,相符设计要乞降《建筑电气工程施工质量验收规范》(GB50303)的划定.质检员施工单位施工员测试员绝缘电阻测试记载(一)专业监理工程师(扶植单位项目专业技巧负责人)质控(电)表4.3.4-2共页第页单位(子单位)工程名称施工单位测试日期817第4页,-共21页气象型号规格兆欧表ZC254装备或线路名称装备位号或体系回路编号500V晴电压等级出厂编号07068401配电箱4AL1W1500500500500500500500500500500W2W3W4W5W6气温(℃)检定单位泉州市计量所检定有用期1123112232℃检定证书编号(QJ)D104/0900197W7100W8W9ABBCCA绝缘电阻实测值︵MΩ︶ANBNCNAPEBPECPENPEAEBECENE消失问题处理情形结论50020080500100500500200200100200500200500500200500无经测试:线路绝缘优越,相符设计要乞降《建筑电气工程施工质量验收规范》(GB50303)的划定.质检员施工单位施工员测试员绝缘电阻测试记载(一)专业监理工程师(扶植单位项目专业技巧负...