电脑桌面
添加小米粒文库到电脑桌面
安装后可以在桌面快捷访问

中心机房搬迁工程方案设计VIP免费

中心机房搬迁工程方案设计_第1页
1/22
中心机房搬迁工程方案设计_第2页
2/22
中心机房搬迁工程方案设计_第3页
3/22
目次1.概述...................................................................................................11.1工程概况.......................................................................................................11.2项目提出的背景...........................................................................................12.搬迁工程包含的内容..........................................................................13.电源专业............................................................................................13.1灵宝中心机房电源设备现状......................................................................13.2电源配套方案...............................................................................................24.传输专业..........................................................................................34.1传输设备现状...............................................................................................34.2灵宝机房搬迁涉及到的业务......................................................................44.3割接总体思路..............................................................................................54.4割接后网络拓扑结构图.............................................................................54.5SDH设备搬迁方案设备配置......................................................................64.6WDM搬迁原有设备配置............................................................................74.7传输专业割接方案:..................................................................................95.数据汇聚..........................................................................................115.1数据汇聚现状............................................................................................115.2数据汇聚设备搬迁优化方案..................................................................126.接入网............................................................................................136.1接入网设备现状........................................................................................136.2接入网设备搬迁方案..............................................................................136.3接入网设备需求.......................................................................................147.光电线缆专业...................................................................................157.1光电缆线路现状........................................................................................157.2光缆搬迁方案............................................................................................168.投资估算...............................................................错误!未定义书签。1.概述1.1工程概况本工程为中心机房搬迁工程,按照安全可靠的原则,结中心机房现有设备及组网现状,充分考虑搬迁的经济效益,并对现有的城域网进行优化调整,制定灵宝中心机房设备搬迁及优化方案。1.2项目提出的背景中心机房位于位于长安路与弘农路交叉口新华书店二楼,安装有传输、交换、数据设备和配套电源设备,为租用机房,租用面积为195平方米左右。现有中心机房所处的建筑物根据市政规划需要进行拆迁,因此灵宝中心机房的设备也需要进行搬迁。新选机房位于五龙路和田宝路交叉口往南100米,租用老干部局1楼及地下1楼区域用于生产、办公以及营业厅。根据规划,机房面积约为200平方米,初期使用100平方米,需要对机房进行改造才能做为通信机房使用。在上述背景下,三门峡市电信分公司委...

1、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
3、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。

碎片内容

中心机房搬迁工程方案设计

确认删除?
VIP
微信客服
  • 扫码咨询
会员Q群
  • 会员专属群点击这里加入QQ群
客服邮箱
回到顶部