环氧树脂玻璃钢防腐防水工程专项施工方案编制人:审核人:审批人:北京 ** 建设集团有限责任公司目录一、编制依据 ······························································ 3 二、工程概况 ······························································ 3 三、施工安排: ··························································· 3 四、施工准备 ······························································ 4 五、施工方法 ······························································ 8 六、质量标准和验收····················································10 七、施工注意事项及保护措施 ······································· 11 一、编制依据1.工程相关文件,设计图纸;2.施工现场条件和实地勘察资料;3. 《地下工程防水技术规范》 《地下防水工程质量验收规范》(GB50108-2001、GB50208-2002)、《新型沥青卷材防水工程技术规范》(北京市标准 DBJ01-16-94)《建筑防水工程手册》、《新型建筑材料实用手册》;4. 《北京市地下防水工程推荐做法》(京95TJ3);5. 《建筑构造通用图集》(地下工程防水 -88J6 );6. 《建筑工程质量检验评定标准》 (GBJ301-88);7. 《北京市地方标准》建筑防水材料;二、工程概况本工程位于北京市 ** 地区,由地上多高层住宅和地下车库 (局部为纯地下车库)及配套设施组成。建筑总面积为26334m2, 地下建筑面8526m2;地上建筑面积为 17808 m2。地上 6、10、12层,地下 2层。工程结构形式为剪力墙结构,基础形式为梁筏式基础。消防水池位于西侧地下二层,底板、内壁、顶棚采用三布四涂玻璃钢防腐防水材料处理。三、施工安排:施工人员持证上岗,保证所有施工人员都能按有关操作规程,规范及有关工艺要求施工。对于复杂的施工分项以及重要的施工部位,思想建设事先编制具体施工方案。事先准备本工程...