公共建筑热工性能检验方法国家建筑工程质量监督检验中心2010.031目录1 《公共建筑节能检验方法》编制目的、意义.........................................错误!未定义书签。2 建筑热工性能检验和前期准备..............................................................错误!未定义书签。2.1检验内容2.2前期准备3 非透光外围护结构热工性能检验...............................................................................................53.1检验范围和内容.................................................................................错误!未定义书签。3.2检测方法...............................................................................................................................54 透光围护结构热工性能检验.......................................................................................................84.1定义.......................................................................................................................................84.2检验范围和内容...................................................................................................................84.3外遮阳检验4.4透明幕墙和采光顶检验.......................................................................................................94.5外通风双层幕墙隔热性能检测5 建筑外围护结构气密性检验.....................................................................................................125.1检验范围.............................................................................................错误!未定义书签。5.2外围护结构整体气密性能检测.........................................................................................135.3外窗和透明幕墙气密性检验错误!未定义书签。21、《公共建筑节能检验方法》编制目的、意义公共建筑包含办公建筑(包括写字楼、政府办公楼等),商场建筑(如商场、金融建筑等),旅游建筑(如旅馆饭店、娱乐场所等),科教文卫建筑(包括文化、教育、科研、医疗卫生、体育建筑等),通讯建筑(如邮电、通信,广播用房等)以及交通运输用房(如机场、车站建筑等)。我国现有公共建筑面积约 45 亿...