预制二队上锁挂签管理办法目 录1. 目的和适用范围......................................................................................................................................11.1 。 目的 ..................................................................................................................................................... 1 1 。 2. 适用范围 ............................................................................................................................................. 1 2. 管理要求 ................................................................................................................................................. 1 3 。 相关人员职责 ........................................................................................................................................ 8 附录 A 能量隔离方案 ................................................................................................................................... 9 附录 B 安全锁具种类 .......................................................... ERROR: REFERENCE SOURCE NOT FOUND 附录 C 有害能量隔离准则建议 ................................................................................................................ 11 1. 目的和适用范围 1.1. 目的为强化能量和物料隔离管理,防止危险能量和物料意外释放,特制定本标准。注:上锁挂签仅能防止误操作,对于蓄意的行为,并不能产生作用。1.2. 适用范围本标准适用于预制二队,重新部署和施工工程以及为公司服务的承包商.应用于有可能发生危险能量和物料意外释放并需要进行控制的作业活动。本标准中,锁及标签,用于法律规范系统的隔离点,以确保人员﹑设备在上锁系统内的安全.“安全锁"及“危险禁止操作"标签仅能防止人员的不经心操作,对于一些蓄意的行为,并不能产生作用。2. 管理要求2.1.基本要求在进行非常规作业时,为避开设备设施或系统区域内蓄积危险能量或物料的意外释放,对所有危险能量和物料的隔离设施均应上锁挂签.隔离或控制危险能量和物料的方式包括但不限于:—- 断开电源或对电容器放电;—— 隔离压力源或释放压力;-— 停止转动设...