大庙镇600KW光伏电站10kV升压站接入发案6.1编制依据....................................................................................................................386.2电气一次设计............................................................................................................396.2.1光伏并网电站接入电力系统的方式............................................................396.2.2电气主接线...................................................................................................396.2.3主要电气设备选择........................................................................................406.2.5过电压保护及接地........................................................................................436.2.7电缆敷设与防火............................................................................................456.2.8电气设备布置..................................Error:Referencesourcenotfound6.2.9主要电气设备表..............................Error:Referencesourcenotfound6.3电气二次设计..............................................................................................................456.3.1电站的综合自动化系统................................................................................456.3.2计算机监控系统..............................Error:Referencesourcenotfound6.3.3系统继电保护................................................................................................466.3.4调度自动化......................................Error:Referencesourcenotfound6.3.5直流及UPS电源系统....................................................................................486.3.6视频安防系统................................................................................................486.3.7火灾自动报警系统........................................................................................486.3.8环境监测系统................................................................................................496.3.9电气二次设备布置........................................................................................496.3.10电气二次设备..............................................................................................49386.1编制依据项目设计遵循以下标准、规范:《高压/低压预装箱式变电站选用导则》(DL/T537-2002)《导体和电器选择设计技术规定》(DL/T5222-2005)《电能量计量系统设计技术规程》(DL/T5202-2004)《电测量及电能计量装置设计技术规程》(DL/T5137-2001)《电力系统调度自动化设计技术规程》(DL5003-2005)《电测量及电能计量装置设计技术规程》(DL/T5137-2001)《电网调度管理条例》(中华人民共和国国务院令第115号)《建筑设计防火规范》(GB50016-2006)《继电保护和安全自动装置技术规程》(GB/T14285-2006)《电力工程电缆设计规范》(GB50217-2007)《电力装置的继电保护和自动装置设计规范》(GB/T50062-2008)《光伏系统并网技术要求》(GB/T19939-2005)《光伏发电站接入电力系统技术规定》(GB/T19964-2012)《电力设施抗震设计规范》(GB50260-2013)《3~110kV高压配电装置设计规范》(GB50060-2008)《建筑物防雷设计规范》(GB50057-2010)《交流电气装置的接地设计规范》(GB/T50065-2011)6.2电气一次设计6.2.1光伏并网电站接入电力系统的方式根据并网光伏电站的建设规模及滁州地区的电网现状,初步确定在场内建设1座10kV开关站,送入距本开关站附近的10kV电网。本光伏电站最终接入系统方案以接入系统专题报告的审查意见为准。光伏电站工程接入电力系统方式如下:光伏组件以9路0.38kV集电线路接入本项目新建的10kV...