目 录1.工程概况...............................................................................................................22.编制根据...............................................................................................................23.编制范畴...............................................................................................................24.材料选用...............................................................................................................25.脚手架搭设、使用、拆除...................................................................................26.构造规定.............................................................................................................77.质量确保方法.....................................................................................................88.安全确保方法.....................................................................................................81.工程概况**************,本工程基础型式普通为大块式,地坑式及框架构造混凝土平台,其中镀铝锅基础、活套基础等深基础分别为-7.5m、-5.8m、-6.7m 等不同深度,电气室外墙最高处为 10.2m。其它基础脚手架高度均在 7.5m 下列。2.编制根据《建筑施工扣件式钢管脚手架安全技术规范》(JGJ130-)《建筑构造荷载规范》(GB50009-)《建筑施工高处作业安全技术规范》(JGJ80-91)《建筑施工手册(第四版)》3.编制范畴连退线设备基础,连退入口、中间、出口电气室等 II 标段内施工范畴,内外脚手架搭设、使用及拆除,其中用于承重的支撑架另见专项方案,本方案不包含此部分内容。4.材料选用本工程均采用扣件式钢管脚手架,采用 φ48*2.7 的钢管搭设,局部不能采用钢管支撑的可采用木方支撑,支撑在基坑土壁上的,支撑底部垫木块。严禁不同材料和连接方式的脚手架杆配件混用。脚手板采用竹跳板或者木跳板。5.脚手架搭设、使用、拆除5.1 脚手架的搭设为确保安全性和稳定性,本工程基本使用双排脚手架,个别高度较小且使用时间不长的部位采用单排脚手架。搭设最大高度 10.2m,立杆采用单立杆,搭设尺寸为:横距为 1m,纵距为 1.5m,大小横杆的步距为 1.8m;内排架距离墙长度为 0.25m;大横杆在上,搭接在小横杆...