下载后可任意编辑目录1、工程概况.......................................................................................................23、施工准备.......................................................................................................34、外架设计.......................................................................................................35、脚手架搭设的技术要求..............................................................................36、外架搭设注意事项......................................................................................77、验收及验评标准...........................................................................................88、拆除................................................................................................................89、安全防护措施...........................................................................................10910 悬挑架计算..................................................................................................1011、应急措施……………………………………………………………..261、工程概况本工程为广西防城港交通稽查处综合楼工程,位于防城港市区。为框剪结构,抗震设防烈度 6 度,结构安全等级二级,综合楼地下 1 层,地上 18层外加 1 层楼中楼。综合楼檐口高 65.37m,综合楼建筑物长 54.2m,宽1下载后可任意编辑23.2m; 工程总建筑面积约为 17000㎡1)、1~7 层采纳落地式脚手架上部采纳悬挑架每 6 层挑一次。1~7 层采纳落地钢管外架。7-19 层(标高正负零)起用悬挑式外脚手架,悬挑总高度 36m,分 2 段悬挑,每 18m 为一段用 I18工字钢悬挑。2、编制依据1、广西防城港交通稽查处综合楼项目工程施工图纸;2、广西防城港交通稽查处综合楼项目工程施工组织设计;3 、 《建筑施工扣件式钢管脚手架安全技术法律规范》 JGJ130-2001(2024 年版);4、《建筑施工手册》第四版缩印本;5、《建筑结构荷载法律规范》GB50009-2001;6、《建筑施工高处作业安全技术法律规范》JGJ80-91;7、《建筑施工安全检查标准》JGJ59-99;8、《施工现场临时用电安全技术法律规范》JGJ46-2024;9、现场实际情况;10、恒智天成安全计算软件。3、施工准备1、...