E 故障功能默认值最小值最大值数据描述1 故障历史* * * 1=最近纪录按箭头健滚动故障纪录2 清除故障历史* 0 1 设定 1 时清除故障纪录从 E 菜单中清除故障纪录d 驱动故障1 电梯参数功能默认值最小值最大值数据描述必需1 主楼层1 ** ** 楼层数选择主入口楼层 , 对下集选非常重要 , 因为所有的外呼都朝向主楼层 . 2 控制模式2 1 6 1=SBC ,2=DC ,3=FC,4=PB ,5=MPB ,6=FC 带 DIA 外呼集选方式 , SBC= 单按钮集选 , DC= 下集选 , FC=全集选, PB= 按钮 ,MPB= 记忆按钮有 DIA. 3 液压电梯0 0 7 0=没有, 1=液压梯, 2=防滑行, 3=液压 +液缸限位开关, 4=防滑行 +液缸限位开关5=KCM831 Hydro with telescopic jacks 6=KCM831 Hydro with PPS 7=KCM831 Hydro with telescopic jacks + PPS安全4 PIN code in use 0 0 1 0=PIN code not in use 1=PIN code in use Enables or disables the PIN code features. 5 PIN Code Activated Features and Car Call PIN Code Locking (PCL) Setup 0 0 304 UI Range 0 to 99 0=Setup of PCL and PIN codes accepted 1=Define floors of locked group 1 2=Define floors of locked group 2 ... 63=Define floors of locked group 63 ------------------------------------------------- UI Range 100's 1-00=Reset (clear) all locked groups 1-01=Reset (clear) locked group 1 1-02=Reset (clear) locked group 2 ... 1-63=Reset (clear) locked group 63 ------------------------------------------------- UI Range 200's 2-00=Set PIN code for Master group 2-01=Set PIN code for group 1 2-02=Set PIN code for group 2 ... 2-63=Set PIN code for group 63 ------------------------------------------------- UI Range 300's Set PIN code for PIN activated features: 3-01=PRC 3-02=OSS 3-03=OCL 3-04=OCV UI Range 0 to 99 Define the floors that are members of each PIN code locked group. UI Range 100's Clear the floors that were set via 1-5-1 to 1-5-63. Individual groups can be cleared, or all groups can be cle...