发电有限公司#2机组INFIT优化控制系统热态调试方案目录0编写依据....................................................................................................................................11调试目的....................................................................................................................................12机组热态调试前准备工作.........................................................................................................13INFIT协调优化控制系统试验..................................................................................................13.1INFIT协调优化控制系统初次投入..............................................................................23.2INFIT协调优化控制系统变负荷试验..........................................................................33.3INFIT协调优化系统正常运行检验..............................................................................54INFIT汽温优化控制系统试验..................................................................................................54.1INFIT汽温优化控制系统初次投入..............................................................................54.2INFIT汽温优化控制系统定值扰动试验......................................................................64.3INFIT汽温优化控制系统变负荷扰动试验..................................................................75INFIT脱硝优化控制系统试验..................................................................................................75.1INFIT脱硝优化控制系统初次投入..............................................................................75.2INFIT脱硝优化控制系统定值扰动试验......................................................................85.3INFIT脱硝优化控制系统变负荷扰动试验..................................................................96凝结水变负荷特性试验.............................................................................................................96.1500MW负荷点试验..........................................................................................................96.2750MW负荷点试验........................................................................................................107INFIT凝结水优化系统试验....................................................................................................117.1INFIT凝结水优化系统初次投入................................................................................117.2INFIT凝结水优化系统定值扰动试验........................................................................127.3INFIT汽温优化控制系统变负荷扰动试验................................................................128安全措施:................................................................................................................................120编写依据0.1《火电厂启动调试工作规定》0.2“火力发电厂分散控制系统技术规范”(G-RK-95-51)电规发(1995)74号文0.3《火力发电厂模拟量控制系统验收测试标准》(DL/T657-2006)0.4《1000MW中间再热凝汽式汽轮发电机技术说明书》0.5《1000MW直流炉技术说明书》0.6《1000MW机组CCS及AGC控制策略SAMA图》0.7《1000MW机组汽轮机电液调节系统SAMA图》1调试目的本项目设计采用全新的实时优化控制装置INFIT系统取代#2机组原有DCS中的AGC控制系统、过热汽温控制系统和再热汽温控制系统。本次调试通过机组动态特性试验、INFIT投/切扰动试验、各项定值扰动试验和变负荷试验整定INFIT系统控制参数...