楼板计算书日期: 3/23/2025时间: 9:08:57:81 am一、基本资料: 1、房间编号: 1 2、边界条件(左端/下端/右端/上端):铰支/铰支/固定/固定/ 3、荷载: 永久荷载标准值:g = 3.50 kN/M2 可变荷载标准值:q = 0.50 kN/M2 计算跨度 Lx = 7800 mm ;计算跨度 Ly = 3000 mm 板厚 H = 80 mm; 砼强度等级:C30;钢筋强度等级:HPB235 4、计算方法:弹性算法。 5、泊松比:μ=1/5. 6、考虑活荷载不利组合。二、计算结果: Mx =(0.01108+0.06778/5)*(1.35* 3.5+0.98* 0.3)* 3.0^2 = 1.10kN·M 考虑活载不利布置跨中X向应增加的弯矩: Mxa =(0.00988+0.11172/5)*(1.4* 0.3)* 3.0^2 = 0.07kN·M Mx= 1.10 + 0.07 = 1.17kN·M Asx= 245.64mm2,实配φ 8@200 (As = 251.mm2) ρmin = 0.307% , ρ = 0.314% My =(0.06778+0.01108/5)*(1.35* 3.5+0.98* 0.3)* 3.0^2= 3.13kN·M 考虑活载不利布置跨中Y向应增加的弯矩: Mya =(0.11172+0.00988/5)*(1.4* 0.3)* 3.0^2 = 0.25kN·M My= 3.13 + 0.25 = 3.38kN·M Asy= 277.81mm2,实配φ 8@180 (As = 279.mm2) ρmin = 0.307% , ρ = 0.349% Mx' =0.07760*(1.35* 3.5+0.98* 0.5)* 3.0^2 = 3.64kN·M Asx'= 366.56mm2,实配φ10@150 (As = 524.mm2,可能与邻跨有关系) ρmin = 0.307% , ρ = 0.654% My' =0.12258*(1.35* 3.5+0.98* 0.5)* 3.0^2 = 5.75kN·M Asy'= 485.38mm2,实配φ 8@100 (As = 503.mm2,可能与邻跨有关系) ρmin = 0.307% , ρ = 0.628%三、跨中挠度验算: Mk -------- 按荷载效应的标准组合计算的弯矩值 Mq -------- 按荷载效应的准永久组合计算的弯矩值(1)、挠度和裂缝验算参数: Mk =(0.01108+0.06778/5)*(1.0* 3.5+1.0* 0.5 )* 3.0^2 = 0.89kN·M Mq =(0.01108+0.06778/5)*(1.0* 3.5+0.5* 0.5 )* 3.0^2 = 0.83kN·M Es = 210000.N/mm2 Ec = 29791.N/mm2 Ftk = 2.01N/mm2 Fy = 210.N/mm2(2)、在荷载效应的标准组合作用下,受弯构件的短期刚度 Bs: ①、裂缝间纵向受拉钢筋应变不均匀系数 ψ, 按下列公式计算: ψ = 1.1 - 0.65 * ftk / (ρte * σsk) (混凝土法律规范式 8.1.2-2) σsk = Mk / (0.87 * ho * As) (混凝土法律规范式 8.1.3-3) σsk...