600MW超临界无烟煤“W”火焰锅炉低温过热器超温缘故分析Cause Analysis on Overheating in the Low Temperature super-heater for a W-shaped Flame Anthracite Coal Boiler of 600 MW Supercritical Unit黄伟 1,李文军 1,彭敏 1,熊蔚立 1,陈跃华 2,谢小红 2,邹自敏 21 湖南省电力公司试验讨论院,湖南 长沙市 410007 ;2 大唐华银金竹山火力发电分公司,湖南 冷水江市 417505HUANG Wei1, LI Wen-jun1, PENG Min1 , XIONG Wei-li1, CHEN Yue-hua2, XIE Xiao-hong2, ZOU Zi-min2,1 Hunan Electric Power Test and Research Institute, Changsha 410007, China2 Datang Huayin Jinzhushan Thermal Power Generation Branch Company, Lengshuijiang 417505,China关键词:600MW 超临界机组;“W”火焰锅炉;无烟煤;低温过热器;超温中图分类号:TK227
1 文献标识码: 文章编号:Abstract: Overheating existed in low temperature super-heater while debugging in W-shaped flame anthracite coal boiler of 600 MW supercritical unit of Datang Huayin Jinzhushan Thermal Power Generation Branch