目 录1.编制依据..............................................................................................................................22. 概况简介 .............................................................................................................................. 1 3. 处理措施 .............................................................................................................................. 2 3.1 后浇带防水处理 ................................................................................................................ 2 3.2 外墙面渗水措施 ................................................................................................................ 3 3.3 回填土中盲沟设置 ............................................................................................................ 5 3.4 B3 ~ B4 层外墙内防水 ...................................................................................................... 6 4. 附录:费用合计 .................................................................................................................. 6 1. 编制依据《地下工程防水技术法律规范》 GB50108-2001KINDPERSON 防水材料技术说明书2. 概况简介结构施工阶段设置在底板后浇带中的抽水井封堵完毕,底板防水修复完成,且浇筑完底板后浇带后,发现 B4 层外墙后浇带防水搭接处出现大量涌水,同时,外墙面在 B4 层底板标高处出现 30 多处沿墙风光竖向裂缝的渗水,并且渗水点主要集中在南侧的 A 轴~G 轴、P轴~V 轴、北侧的 N 轴~L 轴 B4 层外墙上,这段外墙上的所有竖向裂缝陆续(间隔 3m 左右)均出现了水印,渗水点处水印均从 B4 层底板标高处首先出现,随着时间的推移,渗水点处水印不断上升,除上述几跨外,其它跨的外墙上基本无渗水现象。到目前为止,经统计:B4层外墙渗水处多达 44 处,并且可能继续增加。经过现场勘查和施工过程的分析初步得出以下结论:由于降水井封堵后,造成地下水压上升,第三排地连墙锚头处出现大量渗水,水流沿外墙后浇带处的防水搭接部位大量流入地下 4 层,同时还沿外墙周圈局部防水层搭接部位又渗入外墙与防水层间,最后导致...