外墙及门窗淋水实施办法一、目的: ............................................................................................................................... 2二、适用范围: ....................................................................................................................... 2三、淋水时间节点:............................................................................................................... 2四、选用材料: ....................................................................................................................... 2五、检查方法: ....................................................................................................................... 2六、相关人员配合:............................................................................................................... 5七、注意事项: ....................................................................................................................... 6外墙及门窗淋水实施办法一、目的:确保外墙及门窗交付业主正常使用,杜绝渗漏水的现象发生,交付前必须对此项工作做系统全性的排查整改。降低交付质量缺陷点, 提升交房后业主质量满意度。二、适用范围:适用于所有在建项目。三、淋水时间节点:工程淋水检验的开始时间应在外保温工程(北方区域工程才有)、外窗安装工程完成后,外墙涂料等装饰工程开始前实施外墙淋水检验。四、选用材料:主要材料、设备:1、淋水管:内径 20mmPPR 管、PPR 管件;2、喷水装置:高压手动喷雾器;3、固定或悬垂用具:铁钉、铁线、绳子等。注:由被验收检查施工单位提供相应的专业验收工具,确保外墙、窗户的淋水工作正常开展;施工单位若没有准备工具或委托项目部办理,并由项目部代购, 费用由施工单位承担。五、检查方法:1、 外墙淋水时间为 12 小时,每 5 层为一个检验单位(小于5 层按 5 层计算);2、 淋水开始前应关闭本墙面上的所有窗户;3、 淋水管取水点为每户预留的自来水给水点,出水压力为 0.2Mpa(出水口压力需采用压力表实测) 。为保证淋水水量均匀, 每户的取水点均应连接在淋水管网上。淋水管喷水装置4、 淋水管从被淋水层上一层户内外窗引出,确保外墙体的每个角落均可以覆...