目 录 一、编制依据..................................................2 二、工程概况..................................................2 三、方案选取..................................................2 四、脚手架搭设方法............................................3 A、外脚手架................................................3 B、出入口安全防护棚........................................6 C、马道....................................................6 D、悬挑防护棚..............................................7 E、卸料平台................................................8 F、脚手架验收..............................................8 五、质量要求..................................................8 六、安全技术措施..............................................9 A、脚手架搭设安全技术措施..................................9 B、脚手架拆除安全技术措施..................................9 C、脚手架使用规定..........................................9 七、落地式外架计算书..........................................10 八、悬挑式外架计算书..........................................15 (一)、有阳台位置悬挑计算书...............................15 (二)、无阳台位置悬挑计算书...............................22 一、编制依据: 1、《建筑施工扣件式钢管脚手架安全技术规范》(JGJ130-2001) 2、《建筑施工安全检查标准》(JGJ59-99) 3、建筑施工高处作业安全技术规范(JGJ80—91) 4、密目式安全网(GB16909—1997) 5、工程设计图纸 6、施工组织设计 二、工程概况: 风华盛世住宅小区(一期工程)2#楼位于都匀市北片区经济开发区龙山大道北转盘西侧,建筑层数为地下一层,地上 11+1层,房屋建筑高度为 36.55m,屋面最高41.3m,结构类型为框剪结构,总建筑面积为 14410.7m2。 三、方案选取: 本工程拟定 6F以下采用落地式双排钢管脚手架,6F以上采用 18型工字钢悬挑式钢管双排脚手架,其中阳台位置工字钢按 6m一根下料,无阳台位置按 3m一根下料,阳台位置悬挑外架必须注意:内立杆离阳台边缘不超过 5cm,搭设时应紧靠阳台边。 所有双排外脚手架立杆均采用:横距 1m,纵距 1.5m ,内立杆距建筑物外墙皮距离 b=0.15m,脚手架步距...