智能型火灾信息显示及智能疏散指示系统安装及调试方案目录1、要求及布线.......................................................................................................................................................-3-1.1、施工前准备...........................................................................................................................................-3-1.2、钢管内穿线、布线、校线...................................................................................................................-3-1.3、线槽内配线施工方法...........................................................................................................................-4-1.4、外接线预留长度...................................................................................................................................-5-1.5、线路电阻测量.......................................................................................................................................-5-2、系统设备安装...................................................................................................................................................-5-2.1、主机安装...............................................................................................................................................-5-2.2、系统式电源安装...................................................................................................................................-6-2.3、疏散指示灯安装...................................................................................................................................-7-3、智能疏散系统设备调试...................................................................................................................................-8-3.1、调试前准备...........................................................................................................................................-8-3.2、系统检查...............................................................................................................................................-8-3.3、设备单机调试.......................................................................................................................................-9-3.4、系统设备联动调试...............................................................................................................................-9-4、智能疏散系统竣工验收.................................................................................................................................-10-4.1、所需文件.............................................................................................................................................-10-4.2、系统验收主要包括如下装置.............................................................................................................-10-1.要求及布线1.1、施工前准备1.1.1、在施工前应认真并熟悉设备安装平面图、接线图、系统图。1.1.2、安装人员应熟悉相关设计、施工及验收规范。1.1.3、线材规格:1.1.3.1、36v电源线采用WDZNA-BYJ-2*2.5mm2双色铜芯线,100米其电阻不大于1.5Ω;1.1.3.2、信号支线采用WDZNA-RVS-2*1.5mm2双色双绞多股铜芯线,100米其电阻不大于1.5Ω;1.1.3.3、信号总线采用WDZ-RVS-2*1.5mm2双色双绞多股屏蔽铜芯线,100米其电阻不大于1.5Ω;1.1.3.4、220v电源线采用WDZNA-KVV-3*2.5mm2多色铜芯线,100米其电阻不大于1.5Ω;1.1.3.5、线管采...