电脑桌面
添加小米粒文库到电脑桌面
安装后可以在桌面快捷访问

最新常用电缆电缆载流量表VIP免费

最新常用电缆电缆载流量表_第1页
1/20
最新常用电缆电缆载流量表_第2页
2/20
最新常用电缆电缆载流量表_第3页
3/20
资料1.表8-24BVVB型、BLVVB型、RVVB型电线载流量型号截面/mm2参考外径/mm20°时最大单位长度直流电阻/(欧/km)70°时最小单位长度绝缘电阻/M欧km)25°C空气敷设载流量/A成口口参考质量/(kg/km)BVVB型铜芯2x0.7546x7.024.50.01213422x1.04.8x7.418.10.01116492x1.55.4x8.412.10.01120652x2.56.2x9.87.410.01027972x4.06.8x11.04.610.0085381302x4.07.2x11.54.610.0080381402x6.07.4x12.03.080.0070501792x6.08.0x13.03.080.0065501922x109.6x16.01.830.0065693063x0.754.6x9.424.50.0129.5603x1.04.8x9.818.10.01111703x1.55.4x11.512.10.01113953x2.56.2x13.57.410.0010211423x4.07.0x15.04.610.0085271983x4.07.4x16.24.610.0080272133x6.07.4x17.03.080.0070342653x6.08.0x183.080.0065342843x109.6x22.51.830.006555457BLVVB型铝芯2x2.56.2x9.811.80.01021662x4.06.8x11.07.390.008527822x6.07.4x12.04.910.0070351052x109.6x16.03.080.0065541793x2.56.2x13.511.80.001017952x4.07.0x157.390.008523124资料3x6.07.4x174.910.0070271543x107.6x22.53.080.006542265RVVB型2x0.53.8x6.039.00.01210282x0.753.9x6.426.00.0101335铜芯2x0.755.0x7.626.00.01113442.0.6、1KV聚氯乙烯绝缘电力电缆的载流量铠装VV22、VLV22型电力电缆载流量载流量计算条件1.线芯长期工作温度:70。;2.环境温度:25°;3.埋地深度:1000mm;4.土壤热阻系数:1.0m.°C/W;5.线芯轴间距离:S=2D型号及芯数标称截面积/mm2参考外径/mm载流量推荐值/A成品参考质量/(KG/Km)空气中敷设埋地敷设铜芯铝芯铜芯铝芯铜芯铝芯VV22、VLV22单芯101376599775314250161410178127993892872515.71321031661295273663516.91611252021566484265018.71911482401868135117020.524218730223210506129522.7298231361280137176512024.4347270415323163887315026.43953065083621959101918528.74593565304122395121524031.95544296234833333178330036.26374937085484091214540039.775058281463249722573资料型号及芯数标称截面积/mm2参考外径/mm载流量推荐值/A成品参考质量/(KG/Km)空气中敷设埋地敷设铜芯铝芯铜芯铝芯铜芯铝芯5008436558626706309787651001776VV22、VLV22双芯2x4.016.3342741333883382x6.017.3433453424543792x1020.0584570545894592x1622.0776092717485432x2525.5104811229510297042x3527.812910014911612768252x5026.514611317113314878712x7030.3188144214165217813152x9534.2237184267207280016262x12036.5274213306238336518692x15040.0316245346268405922092x18543.836828639430649842610VV22、VLV223芯3x4.017.0292336284503753x6.018.1372945365384253x1020.8503860467455513x1623.1665179619836753x2526.990701058213448573x3529.31118612799170210253x5031.2129100148115234414243x7034.4165127185142301717253x9538.6206160221176391321583x12041.7242188261203474125073x15045.4281218296229579030233x18551.0328254337261701336143x24057.3386299389302893044983x30061.5445344441342113505447资料型号及芯数标称截面积/mm2参考外径/mm载流量推荐值/A成品参考质量/(KG/Km)空气中敷设埋地敷设铜芯铝芯铜芯铝芯铜芯铝芯3x40081.051940350439115825VV22、VLV224芯4x4.018.2302437295294294x6.019.3383046376414914x1022.5534164499056444x1625.07155836512188044x2529.2947310884169010344x3533.511791132102247915684x5034.3140109157122296317334x7037.8178137196151383121074x9543.1219170234187503226894x12046.3255198268208610531194x15051.0294227301233747537814x18556.2333258338262909745344x24061.3397308393305116644x30069.3464359448347150184x40090.154842551540020202VV22、VLV223+1芯3x4+1x2.517.6302437294954053x6+1x419.1383046376084713x10+1x621.8524064498346033x16+1x1025.57055846511437703x25+1x1628.2937210884160710173x35+1x1630.511388130101206011973x50+1x2537.0142110158123279517113x70+1x3540.7181139198152358120613x95+1x5045.0222172236183467626113x120+1x7049.725820...

1、当您付费下载文档后,您只拥有了使用权限,并不意味着购买了版权,文档只能用于自身使用,不得用于其他商业用途(如 [转卖]进行直接盈利或[编辑后售卖]进行间接盈利)。
2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。
3、如文档内容存在违规,或者侵犯商业秘密、侵犯著作权等,请点击“违规举报”。

碎片内容

最新常用电缆电缆载流量表

确认删除?
VIP
微信客服
  • 扫码咨询
会员Q群
  • 会员专属群点击这里加入QQ群
客服邮箱
回到顶部