论文对小电流接地系统单相接地保护选线方案的讨论学科(专业):电力系统与其自动化摘 要小电流接地方式由于在保证运行维护人员的安全、过电压水平、设备绝缘水平、经济性等方面存在诸多的优点,所以一直被应用于我国的中低压电网中。在生产实际中,中低压线路的故障,有 70%以上都是单相接地故障,所以,寻找一种选线准确率高的保护装置,仍然具有相当重要的理论和有用价值。文章主要针对小电流系统单相接地选线方法进行了分析,讨论了小电流接地故障暂态算法和稳妥算法,并重点分析了多判据信息融合选线方法。文章最后进行了小电流系统选线方法问题的分析。关 键 词:小电流接地系统;单相接地;故障选线;多判据论文类型:应用讨论Title:Project of line selection for small current grounding system of single-phase grounding protection research Speciality:Electricity and its automationApplicant:Xiong ShuweiSupervisor:Duan JiandongABSTRACTSince small current grounding operation and maintenance personnel in ensuring the safety of over-voltage levels, equipment insulation levels, and there exist many economic advantages, it has been applied to low-voltage power grid in China. In actual production, the low-pressure line failure, more than 70% are single-phase ground fault, therefore, to find a select line of high accuracy of the protection device, still has a very important theoretical and practical value.This article mainly current system of small single-phase line selection method of analysis of the small current grounding fault transient algorithm and secure algorithm, and analyzed the wavelet analysis and its electric power system. Finally a simulation study.KEY WORDS: system with non-effectively earthed neutral;single-phase-to-ground fault;fault line selection;TYPE OF THESIS:application目 录摘 要 IABSTRACTIII目录 V1 绪论 11.1 课题讨论背景与意义 11.2 课题讨论现状 21.3 论文的主要容 32 小电流接地系统单相接地选线方法分析与探讨 52.1 小电流接地故障稳态算法 5...