目录第一章施工协调与配合....................................3一、与总包单位的配合......................................3二、与二次装修单位的配合..................................5三、与其它分包专业的配合..................................8四、与设计及甲方的配合...................................10五、与监理及其他单位的配合...............................11六、施工过程中重要配合点.................................11第二章施工部署..........................................13一、施工准备.............................................13二、施工平面布置.........................................14三、施工安排.............................................14四、施工制度.............................................15五、施工计划.............................................15第三章施工方案.........................................15一、通风系统的安装.......................................151、主要施工程序..........................................152、通风管道及部件的加工制作..............................153、通风管道与部件的安装..................................184、风管的严密测试........................................185、管道保温..............................................216、风口的安装............................................227、风管吊装..............................................228、风管配件的联接........................................23二、变频多联机空调主要施工方法及技术措施.................241、室外机基础............................................242、室外机安装位置选择....................................253、室外机安装............................................254、室外机汇总管、分歧管安装..............................255、多联机室内机施工要求..................................266、制冷剂连接管的存放....................................277、制冷剂连接管的安装....................................288、喇叭管加工............................................319、分歧管的安装..........................................3210、吹洗.................................................3411、连接管的保压检漏.....................................3512、室内机排水管的安装...................................3613、保温.................................................3614、通讯线的连接和室内机地址拨码.........................3815、通讯线的连接.........................................3816、搬运室外机...........................................3817、安装室外机...........................................3918、连接上室内外机、保压检漏.............................3919、连接室内、外机.......................................3920、连接室外机...........................................4021、连接室内机...........................................4022、保压检漏(将连接管连接上室内外机后的保压检漏).......4023、抽真空...............................................4124、追加制冷剂...........................................42第一章施工协调与配合一、与总包单位的配合总包单位肩负着工程整体质量责任,所以需对工程各专业统筹安排,统一管理。作为通风空调的专业分包单位,应服从心总包单位的协调管理,执行总包方的统一进度安排,配合总包完成预期质量目标、进度目标即安全文明生产目标。同时,总包单位的各种技术服务与现场提供的生产条件完备是各分包单位顺利进行施工的前提条件。我们配合的原则是:服从统一协调施工相对先进、配合积极主动、系统完善负责1、积极配合的工作(1)遵守总包方制定的各项现场管理制度,服从总统施工目标;(2)积极参加总包协调...