Produ ctsPilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, GermanyTelephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.deBase unitsPNOZ m1pNSG-D-2-359-2006-02Base units from the PNOZmulti modu-lar safety systemApprovalsUnit features` Can be configured in the PNOZmulti Configurator` Positive-guided relay outputs:– 1 safety output in accordance with EN 954-1, Cat. 4or 2 safety outputs in accord-ance with EN 954-1, Cat. 2` Semiconductor outputs:– 2 safety outputs in accordance with EN 954-1, Cat. 4or 4 safety outputs in accord-ance with EN 954-1, Cat. 3– 1 auxiliary output` 4 test pulse outputs` 1 cascading input and outputcan also be used as a standard out-put ` 20 inputs for connecting:– E-STOP pushbutton– Two-hand button– Safety gate limit switch– Reset button– Light barrier– Scanner– Enable switch– PSEN– Operating mode selector switch– Safety mat` Muting function` Max. 8 expansion modules and 1 fieldbus module can be connected` LED indicator for:– Diagnostics– Supply voltage– Output circuits– Input circuits` Test pulse outputs used to detect shorts across the inputs` Monitors shorts between the safety outputs` Plug-in connection terminals (either cage clamp terminal or screw termi-nal)Unit descriptionThe PNOZmulti modular safety system is used for the safety-related interrup-tion of safety circuits and is designed for use in:` Emergency stop equipment` Safety circuits in accordance with VDE 0113 Part 1 and EN 60204-1Chip cardChip cards are available with memo-ries of 8 kByte and 32 kByte. For large-scale projects we recommend the 32 kByte chip card (see chapter contain-ing the order references).The chip card with a memory of 32 kByte can only ...