文章编号: 1007�2284( 2007) 03�0069�03变压器局部放电在线监测技术分析刘海萍, 李正明( 江苏大学电气信息工程学院, 江苏 镇江 212013)� � 摘� 要: 阐述了变压器局部放电在线监测的原理、现状以及在线监测方案如何选择, 分析了变压器局部放电在线监测中的各种干扰及其抑制方法, 并提出了实际监测中分层式抑制干扰的模式, 探析了目前在线监测局部放电所存在的问题。� � 关键词: 变压器; 局部放电; 在线监测; 干扰抑制� � 中图分类号: TM 41 � � � 文献标识码: AAnalysis of On�line Monitoring Technique of Partial Discharge of Power TransformerLIU Hai�ping, LI Zheng�ming( School of Electrical and Information Engineering, Jiangsu Universit y, Zhenjiang 212013, Jiangsu Province)Abstract: In this paper the principle, actualities of on�line monitoring for partial discharge of power transformer are depicted. At thesame time, t he way to choose t he scenario of on�line monitoring is also depicted. Based on the analysis of various int erference in par�t ial discharge on� line monitoring of transformers, the paper proposes some anti�interference techniques, and gives a multi�layer inter�ference suppression model for partial discharge on�line monitoring of transformers. Finally, the paper discusses the problems of on�line monitoring system for partial discharge of pow er t ransformer.Key words: t ransformer; part ial discharge; on�line monitoring; interference suppressing� � 在线监测变压器的局部放电与外施电压下测量变压器的局部放电在技术方法上有很大差异。后者是在变压器脱离电网的状态下用常规方法进行的。它不受电网限制, 处在有效地排除外界干扰的环境下, 灵敏度较高。但是此种情况代替不了变压器在电力系统中的实际运行情况, 也不可能准确反映变压器的绝缘状况及其发展趋势。而变压器局部放电在线监测却与电网紧密相联系, 它通过监测变压器的电信号及时获取反映运行状态的各种物理量, 并对其进行分析处理, 预测运行状况,必要时提供报警和故障诊断信息, 避免...