目 录一、编制说明...........................................................................................................2二、编制依据...........................................................................................................2三、工程概况...........................................................................................................2四、施工准备...........................................................................................................2五、缓冲罐吊装施工方法.......................................................................................3六、“HSE”技术措施..............................................................................................8七、吊装安全质量保证体系岗位职责.................................................................12八、资源需求计划.................................................................................................12九、附图.................................................................................................................14一、编制说明林德气体(吉林)有限公司制氢装置安装工程有我单位承建。PSA 单元的 PSA 净化气缓冲罐(位号:1801D01)为立式储罐,是现场最重的设备,安装在地面基础上。为确保PSA 净化气缓冲罐吊装任务的一次成功,达到用户满意,特编制此方案。二、编制依据1、林德气体(吉林)有限公司制氢装置工程设计资料2、设备安装平面布置图3、PSA 净化气缓冲罐设备装配图4、《大型设备吊装工程施工工艺标准》(SHT3515-2024);5、吊车性能表6、《起重吊装常用数据手册》 人民交通出版社杨文渊编;7、《安全操作手册》三、工程概况1、设备基本情况PSA 净化气缓冲罐由兰州兰石重型装备股份有限公司制造的立式气体储罐。设备筒体为 16MnDR,厚度为 16mm。现场安装在混凝土基础上,裙座支撑。2、设备主要技术参数:序号设备名称设备位号单重(Kg)外形尺寸(mm)吊耳型式安装标高1PSA 净化气缓冲罐1801D0158548Φ4000×16 H=29166管式EL0.300m四、施工准备4.1 施工技术准备4.1.1 施工前要有经过审批的吊装方案,运输和吊装前施工方案要下发到相关技术人员和施工人员手中,认真熟悉此方案,并进行现场技术交底。4.1.2 ...