火电厂温度测量元件故障分析处理火电厂温度测量元件故障分析处理 摘要:温度是热电厂热力控制系统中最重要的参数之一,几十年来随着科技的进步测量技术飞速进展,测量设备也从单一的测量功能向多功能、智能化、精度化进展。本文通过对当今大型火电机组所应用的温度测量装置的种类、基本构造、测量原理,深化的分析了在使用过程中温度元件的故障分析及处理方法,为我公司热控专业施工人员在今后的机组试运过程中做一个技术指导。 关键词:热电偶;热电阻 Abstract: temperature is thermal power plant thermal control system is one of the most important parameters in decades rapid development with the progress of science and technology measuring technology, measuring equipment from a single function to multifunction, intelligence, accuracy. Based on today's large thermal power unit by application of temperature measurement device of the type, basic structure, measuring principle, in-depth analysis of the temperature in the process of using components of fault analysis and processing method of thermal control specialty construction for my company personnel in the unit start-up process to make a technical guidance. Key words: thermocouple; Thermal resistance. 中图分类号:TM621 文献标识码:A 文章编号:2095-2104(2025) 概述 温度信号是热电厂热力控制系统中的一个重要参数,通常一台600MW 的火电机组约有 1000 点左右(北仑百万机组有 3000 多点,其中锅炉壁温 2000 多点),占各类测点总量的 30﹪左右,而且测量范围广。因此测量的准确与否将直接影响机组运行的安全性、稳定性、高效性。 热电偶测量装置 热电偶是火电厂中最常用的温度测量元件之一,其优点是: 1)测量精度高,因热电偶直接与测量介质相接触,不受中间介质影响。 2)测量范围广,常用的热电偶从-50~+1600℃均可连续测量,某些特别的热电偶最低可测 -269℃,最高可测+2800℃. 3)构造简单,使用方便,热电偶通常有两种不同的金属丝组成,而且不受大小和开头的限制,外有保护套管,用起来非常方便。 1.1.热电偶的工作原理: 两种不同成份的导体(称为热电偶丝材或热电极)两端接合成回路...