目 录目 录............................................................................................................................1第 1 章风管水力计算使用说明....................................................................................21.1功能简介................................................................................................................21.2使用说明................................................................................................................31.3注意........................................................................................................................8第 2 章分段静压复得法................................................................................................92.1传统分段静压复得法的缺陷.................................................................................92.2分段静压复得法的特点......................................................................................102.3分段静压复得法程序计算步骤...........................................................................112.4分段静压复得法程序计算例题...........................................................................11第 1 章 风管水力计算使用说明1.1功能简介命 令 名称:FGJS功 能:风管水力计算命令交互:单击【单线风管】【水力计算】,弹出【风管水力计算】对话框,如图 1-1 所示: 图1-1 风管水力计算对话框如果主管固定高度值大于 0,程序会调整风系统中最长环路的管径的高度为设置值。如果支管固定高度值大于 0,程序会调整风系统中除开最长环路管段外的所有管段的管径的高度为设置值。控制最不利环路的压力损失的最大值,如果程序算出的最不利环路的阻力损失大于端口余压,程序会提醒用户。当用户需要从图面上提取数据时,点取搜索分支按钮,根据程序提示选取单线风管。当成功搜索出图面管道系统后,最长环路按钮可用,单击可以得到最长的管段组。计算方法程序提供的三种计算方法,静压复得法、阻力平衡法、假定流速法,可以改变当前的选项卡,就会改变下一步计算所用的方法,而且在标题栏上会有相应的提示。计算结果显示包含搜索分支里面选取的管段的一条回路的各个管段数据...