DOI:10.11973/lhjy-hx201507005饮用水中游离余氯的现场快速测定逯南南1,褚福敏1,肖芙蓉2,周维芳1,宋武昌1,孙韶华1,贾瑞宝1*(1.山东省城市供排水水质监测中心,济南250021;2.山东省图书馆,济南250011)摘要:采用便携式余氯比色计快速测定饮用水中的游离余氯。对便携式余氯比色计进行校正,现场检测余氯的最佳水温为20℃左右,最佳酸度为pH6~7,比色计读数时间应控制在20min内。水中锰、铬等金属离子的干扰可通过添加碘化钾溶液消除。此方法与国家标准GB5749-2006中方法相比较,检测结果无显著性差异。关键词:便携式余氯比色计;余氯;饮用水;快速检测中图分类号:O657.32文献标志码:A文章编号:1001-4020(2015)07-0914-03RapidDeterminationofFreeChlorineResidualinDrinkingWaterLUNan-nan1,CHUFu-min1,XIAOFu-rong2,ZHOUWei-fang1,SONGWu-chang1,SUNShao-hua1,JIARui-bao1*(1.UrbanWaterMonitoringCenterofShandongProvince,Jinan250021,China;2.LibraryofShandongProvince,Jinan250011,China)Abstract:Theportablechlorineresidualcolorimeterwasusedforrapiddeterminationoffreechlorineresidualindrinkingwater.Thecolorimeterwascalibratedonsiteandthedetectionconditionswereoptimized.Theresultshowedthattheoptimaltemperaturewas20℃,andthepHvaluewasbetween6-7.Theinterferenceofmanganese,chromiumandothermetalionscouldbeeliminatedbyaddingpotassiumiodidesolution.TheresultsshowednosignificantdifferencecomparingwiththestandardmethodGB5749-2006.Keywords:Portableresidualchlorinecolorimeter;Chlorineresidual;Drinkingwater;Rapiddetermination余氯是指采用氯化消毒的饮用水处理过程中,接触一定时间后水中残留的氯的含量。余氯有总余氯(包括HOCl、NH2Cl、NHCl2及其它氯胺类化合物),化合余氯(包括NH2Cl、NHCl2及其它氯胺类化合物)和游离余氯(包括HOCl及OCl-等)等3种形态,游离余氯又称自由氯。最常用的水中余氯的测定方法为邻联甲苯胺目视比色法[1]。该方法测定简单,但准确度不高。另外,邻联甲苯胺具有一定的致癌性,不推荐使用。通常实验室中利用N,N-收稿日期:2014-07-05基金项目:国家水体污染控制与治理科技重大专项“南水北调山东受水区饮用水安全保障技术研究与综合示范”课题(2012ZX07404-003)作者简介:逯南南(1984-),女,山东济南人,硕士研究生,主要研究方向为饮用水安全保障。*联系人。E-mail:jiaruibao68@126.com二乙基对苯二胺(DPD)法测定余氯的操作较繁琐,试剂的配制较复杂,不适合现场对水中游离余氯的快速测定。目前已有不少厂家根据DPD法测试原理设计出便携式的比色计及快速测定的试剂包,操作简单、携带方便,能够完成游离余氯的现场快速测定,已广泛应用于环境监测、饮用水及医院污水处理等领域。但对于便携式余氯比色计的使...